Features &Benefits: | 1. 7” color TFT display, high resolution 800×480 dpi; 2. Separated para board: ECG, NIBP, SpO2 board; 3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. 4. Real time S-T segment analysis, and ARR analysis; 5. SpO2 Pitch Tone Variation and Drug Dose Calculation; 6. Parameter waveform and characters color selectable 7. Multi and unique display: Standard, Large font, Trend Coexis, OxyCRG dynamic 8. Standby mode for Energy saving and suspend monitoring; 9. 7-lead ECG waveforms display in phase; 10. Capture dynamic waveforms; 11. Built-in rechargeable lithium battery, and battery volume checking. 12. Efficient resistance to interference of defibrillator and HF knife; 13. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; 14. TCP/IP networking platform enable abundant future upgrade 15. Complete and flexible mounting solution for transportation and in-patient monitoring |
Standard parameters: | 5-lead ECG, RESP, HR, NIBP, SPO2(F-5), 1-TEMP, PR; Optional: Touch Screen, ,EtCO2, SpO2(F-6) Performance Specifications Display: 7’’color TFT Rolling and refreshing waveform display Resolution: 800×480 Multi display selectable including: Large-font display Trend coexist display OxyCRG dynamic view display. Bed-to-bed view display Trace: 4 waveforms Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s Indicator: Power/battery indicator light QRS beep and alarm sound Battery: Rechargeable lead acid cell, 12v/4AH Max.24 hour for charging, 4 hours for continue working Trend: Parameter graphic and tabular trends: 5s/piece,8 hours; 1min/piece,168 hours(24hour×7days) 5min/piece,1000 hours. Storage: NIBP:1000 groups Alarm:200 groups Full disclosure waveforms: 3600S Alarm: User-adjustable High, Medium and Low limits 3-level Audible and visual alarm Networking: Connected to central monitoring system TCP/IP netting platform Recorder: Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Standard Parameter: | ECG: Lead mode: 5 –lead(R,L,F,N,C) Lead selection : I,II,III,avR,avL,avF,V Waveform: 4 channels Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 6.25mm/s; 12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate:/pediatric:15~350bpm Accuracy: +1bpm or +1%,whichecer is greater Resolution: 1bpm Filter: surgery mode:1~20Hz monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Scaling signal: 1mv,+3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detecton: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv Arrhythmia analysis: YES SPO2 Measurement range: 0~100% Resolution: 1% Accuracy: +2%(70-100%);0-69% unspecified Alarm range 0~100% Pluse Rate: range:20~300bpm Resolution:1bpm Error:+1bpm or +2%,whichever is greater NIBP Method: Digital Automatic oscillometric Operation mode : Manual/Automatic/continuous Auto measurement time: Adjustable(1~480min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement tange: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic.Diastolic,Mean RESPIRATION Method: Thoracic impedance Measurement range: Adult:7~120rpm; Neonate/Pediatric:7~150rpm Apnea alarm: YES,10~40s Resolution: 1rpm Accuracy: +2rpm |